Example 6.7
Estimation of the design bearing capacity of a pile group
An offshore pole is going to be founded on a pile group consisting of 4 cylindrical piles, with the geometry shown in the figure below. Determine the short-term design bearing capacity of the pile group, according to AS 2159 provisions, For the specific project, assume a basic geotechnical strength reduction factor φgb equal to φgb = 0.60.

Answer:
In the Example 6.1 we have determined the ultimate geotechnical strength of each single pile with the α-Method as:
1. Ultimate geotechnical strength of pile group considering efficiency, ng:
According to FHWA (2006), pile group efficiency ng for cases where the pile cap is not in firm contact with the ground and s/D = 4 m/1 m =4 (Eq. 6.88) is:
Therefore the ultimate geotechnical strength of pile group considering is (Eq. 6.87):
2. Ultimate geotechnical strength of pile group for block-type failure:
We will apply Eq. 6.89, considering B = 4 m and Z = 4 m i.e., the dimensions of the pile group, not the pile cap (Figure 6.65b). Also, as for the calculation of the skin friction resistance of a single pile, the first 1.5D meters of the pile shaft will not contribute to the friction resistance:
Observe that the ultimate geotechnical strength for block-type failure is grossly larger than the ultimate geotechnical strength considering failure of individual piles, even when pile group efficiency ng < 1 is applied to the latter. This does not come as surprise: Block-type failure can, by definition, be critical only for very dense pile spacings, when the area of the pile group (B ×Z) + 2(B ×L)+ 2(Z ×L) is smaller than the surface area of the individual piles.
3. Design bearing capacity of pile group
The design bearing capacity φgbQf,group is: